Framework agreement for the supply of 0,4 kV, 10 kV and 36 kV cables

Ordregiver
Nexel A/S
Oplyst værdi / estimat
250.000.000 DKK
Frist
Publiceret
11.1.2024
Leveringssted (NUTS)
DK022, DNK

Dataposten opdateret . Datakilder, dækning og beregningsmetode.

Tildeling

Vinderlisten dækker bekendtgørelsen. Denne visning har ikke en sikker kobling mellem hver vinder, delkontrakt, værdi og udløbsdato. Se originalen for fordelingen.

Bekendtgørelsens samlede værdi: 1.096.000.000 DKK
Vinder ikke oplyst
Oplyst værdi: 1.096.000.000 DKK

Beløb er offentliggjorte værdier i bekendtgørelser og kan omfatte flere delkontrakter, rammeaftalelofter og estimater. De viser ikke faktisk omsætning eller forbrug. Valutaer summeres hver for sig uden omregning. Manglende beløb er ikke nul. Se datagrundlag og metode.

Beskrivelse
The tender procedure concerns the award of a framework agreements for the supply of 0,4 kV, 10 kV and 36 kV cables. Lot 1: Low voltage cables: This lot includes 0,6/1kV cables, as specified in Appendix 1: Specifications for requirements regarding low voltage cables (Lot 1) and stated in Appendix 2: Prices and forecasts (Lot 1). Lot 2 Medium voltage cables: This lot includes 12/17,5/36kV cables as specified in Appendix 1: Specifications for requirements regarding medium voltage cables (Lot 2) and stated in Appendix 2: Prices and forecasts (Lot 2). Lot 3: Low and medium voltage cables: This lot includes 0,6/1kV flexible rubber cables and 12/17,5kV flame retardant cables, as specified in Ap-pendix 1: Specifications for requirements regarding low and medium voltage cables (Lot 3) and stated in Appendix 2: Prices and forecasts (Lot 3). All lots are based on a framework agreement with several operators, which is done to ensure a better security of supply. All lots will be awarded to two (2) suppliers. Purchase orders will be awarded by direct award and according to a 60/40 split. The supplier who has submitted the tender with the best price-quality ratio will receive 60 % of all purchase orders issued during the term of the Framework agreements. The supplier who has submitted the tender with the second-best price-quality ratio will receive 40 % of all purchase orders issued during the term of the Framework agreements.

Procedure og udbudsmateriale

Oplysninger fra bekendtgørelsen kan dække flere delkontrakter. Listerne nedenfor er separate uddrag; rækkefølgen kobler ikke et kriterium til en beskrivelse eller delkontrakt. Kontrollér krav, vægtning, frister, optioner og eventuelle rettelser i originalmaterialet.

Proceduretype (kildens kode)

  • neg-w-call

Tildelingskriterier

  • Price
  • Cable temperature
  • Bending radius
  • Handling

Beskrivelser af tildelingskriterier

  • Evaluated on the basis of the overall price for evaluation purposes (referred to in the following as the "evaluation-technical price"). The overall evaluation-technical price is calculated on the basis of the estimated amount for each cable and the estimated amount for drums together with the offered prices. The evaluation technical pris is a summation the total for cables and the total for drums.
  • Evaluated according to evaluable requirement on the lowest cable temperature during the installation by making special precautions based on the scale from -1°C to -15°C.
  • According to evaluable requirement on the lowest bending radius of the cable when laying on the scale from 8 x diameter to 12 x diameter.
  • Evaluated on the following sub-subcriteria: - Cables should be with rip cord - The robustness of the outer sheath - Marking on outer sheath should be durable and easily readable - Cables should be easy to bend
  • Evaluated on the basis of the overall price for evaluation purposes (referred to in the following as the "evaluation-technical price"). The overall evaluation-technical price is calculated as the sum of the items listed in Appendix 2, Price catalogue, multiplied with the estimated volume.
  • evaluated according to evaluable requirement on the lowest cable temperature during the installation by making special precautions based on the scale from -1°C to -15°C.
  • evaluated on the following sub-subcriteria: According to evaluable requirements on the lowest bending radius of the cable when laying on the scale from 8 x diameter to 12 x diameter.
  • Evaluated on the following sub-subcriteria: - Cables should be with rip cord - Robustness of the outer sheath - Marking on outer sheath should be durable and easily readable - Cables should be easy to bend - Cables should hold their form - Shape of cables - Stripping force - Core marking should be durable and easily readable
  • evaluated according to evaluable requirements on the lowest cable temperature during the installation by making special precautions based on the scale from -1°C to -15°C.
  • Evaluated on the following sub-subcriteria: - Cables should be with rip cord - Marking on outer sheath should be durable and easy readable - Cables should be easy to bend - Cables should hold their form - Compound type - Stripping force - Core marking should be durable and easily readable