Gå til hovedindhold
UdbudsScanner
Alle udbud
TED123101-2025

2025-0790984 - Green House Gas Elemental Analyzer Gas Chromatography Combustion quadropol Time of Flight Isotopic Ratio Mass Spectrometry

Oplyst værdi / estimat
6.580.000 DKK
Frist
Publiceret
24.2.2025
Leveringssted (NUTS)
DK042, DNK

Dataposten opdateret . Datakilder, dækning og beregningsmetode.

Tildeling

Vinderlisten dækker bekendtgørelsen. Denne visning har ikke en sikker kobling mellem hver vinder, delkontrakt, værdi og udløbsdato. Se originalen for fordelingen.

Bekendtgørelsens samlede værdi: 6.580.000 DKKKontrakt indgået: 31.1.2025
CVR 21852902Oplyst værdi: 6.580.000 DKK

Beløb er offentliggjorte værdier i bekendtgørelser og kan omfatte flere delkontrakter, rammeaftalelofter og estimater. De viser ikke faktisk omsætning eller forbrug. Valutaer summeres hver for sig uden omregning. Manglende beløb er ikke nul. Se datagrundlag og metode.

Beskrivelse
Purchase a Green House Gas Elemental Analyzer Gas Chromatography Combustion quadropol Time of Flight Isotopic Ratio Mass Spectrometry (GHG-EA-GC-C-qTOF-IRMS) for the accurate identification of stable isotopic ratio and qualification and quantification of thousands of carbon and nitrogen containing compounds, that play a crucial role in ecological interactions in the agricultural environment.

Procedure og udbudsmateriale

Oplysninger fra bekendtgørelsen kan dække flere delkontrakter. Listerne nedenfor er separate uddrag; rækkefølgen kobler ikke et kriterium til en beskrivelse eller delkontrakt. Kontrollér krav, vægtning, frister, optioner og eventuelle rettelser i originalmaterialet.

Proceduretype (kildens kode)

  • neg-wo-call

Tildelingskriterier

  • Quality

Beskrivelser af tildelingskriterier

  • Specific requirements: 1. High resolution GC Mass Spectrometer with MS/MS capability. 2. First mass filter must be a heated Quadrupole, and second mass filter must be a time-of-flight tube 3. Mass accuracy should be <2 ppm RMS. 4. Mass Resolution should be >25,000 and must be independent of acquisition rate 5. Acquisition rate must be from 1 hz to 50 hz and must be independent of mass resolution 6. Enough sensitivity should be there at lower energy also to perform Low energy EI analysis 7. EPC resolution should be 0.001 psi to be able to perform precise retention time locking 8. The elemental analyzer instrument should make use of a single, dynamically heated gas separation column for CO2 and SO2 superior separation of post-combustion gases. It should be possible to analyse nitrogen, carbon and sulfur isotopes from a single organic sample within 10 minutes. The system should not require any tools for routine maintenance with all operations able to be done by hand whilst guaranteeing leak tightness. 9. The IRMS instrument should offer a 100V amplifier as standard providing a 1000 fold working beam size allowing a large range of elemental ratios to be analysed during a single acquisition. It should occupy the smallest possible instrument footprint to preserve laboratory space. The IRMS vacuum chamber must be entirely constructed from 316L stainless steel utilising vacuum welding techniques for the highest vacuum purity and fastest pump down times. The IRMS Instrument should use non-metal, vacuum sealing gaskets which do not deform the sealing face and that can be re-used.

Andre bekendtgørelser i samme CPV-kategori

Nyeste bekendtgørelser med samme firecifrede CPV-kategori. Listen kan omfatte både åbne udbud og historik.